Operation
EL1918 37Version: 1.2.0
Fig.23: Connection tab of the alias device
The Safety Parameters tab contains the parameters of the EL1918 to be set. The parameters are set
separately for each input. Objects 0x8000 and 0x8001 are available for input 1. For all other inputs, the CoE
index is increased by 10hex each, so that objects 0x8070 and 0x8071 are available for input 8.
Fig.24: EL1918 parameters