Transport and storage
42
─── Version: 1.0XPlanar
WARNING
Never transport the mover without a cover
The cover weakens the magnetic field and protects electrical
components from magnetic influences.
The strong magnetic field of the movers can cause crushing in-
juries. Furthermore, EMC interference with electrical components
may occur.
Avoid damage to the components and loss of guarantee
Observe the conditions and the following chapters on transport and
storage.
Disregarding the conditions can lead to damage to the components
and the voiding of the guarantee.
6.1
Conditions
Take care during transport and storage to avoid damage to individ-
ual XPlanar components. Observe the following chapters and main-
tain the following conditions:
• Climate category: 2K3 according to EN 60721
• Temperature: -25°C to +65°C, maximum fluctuation 20K/hour
• Use of the vendor's original packaging
6.2
Long-term storage
Perform recurring inspections
Check the XPlanar state and condition every six months.
Damage to the XPlanar or failure to carry out maintenance can
shorten the service life of the installed components and parts.
Prevent the formation of condensation
Keep the ambient temperature constant. Avoid solar radiation and
high air humidity.
Condensation water can lead to damage during subsequent opera-
tion or to rust formation.
The XPlanar components can be stored for shorter or longer peri-
ods. For storage we always recommend the original packaging.