Local Air-conditioner / User Manual
47 / 396 EN
7 Installaton explanatons
7.5 Water full alarm
The inner water tray inside the air-conditioner has one water level safety switches, it controls water
level. When water level reaches an anticipated height, the water full indicator lamp lights up. (If water
pump is damaged, when the water is full, please remove the rubber blockage at the bottom of unit,
and all water will be drained outside.)
A
B
Hole (A) which is placed at the top, is to be used to extract the water from the mobile air conditioner
(remove the rubber stopper and add the drain hose to the orifice) when there is a lot of humidity in the
room (in continuous drainage) or when the product is operating in dehumidification or heating mode.
Hole (B) which is placed at the bottom, has a tank and is to be used when it is necessary to empty the
tank (water tank alarm). Simply remove the rubber plug and add the drain hose to the hole to drain the
water from the tank.
C
Note:
Attention depending on the filling of the water tank, there will sometimes be a lot of
water to evacuate. Then the ideal would be to empty it outside or empty it over a large
basin to avoid flooding your room.