Manual casting without pyrometer
With the NAUTILUS
®
CC plus, manual casting
without pyrometer is used as an optional
"emergency operation", in case the pyrometer is
malfunctioning/not available.
1. Select the alloy (see page 41).
2. Go to "Settings" > "Program".
3. Deactivate all settings.
4. Optional: Enter log data (see "Setting up the
protocol" on page 40). This data appears in the
casting protocol that is stored on the con-
nected USB flash drive.
• Enter work number, batch and casting quan-
tity and confirm the entry with "OK" or
• Skip the data entry with "Abort".
5. Insert the alloy.
6. Close the crucible door.
7. Confirm the preheating process with "OK".
For some alloys, the preheating process may
be skipped with a second button.
In fast mode, the preheating process starts
upon closing the crucible door.
The temperature cannot be
measured and thus not be limited
without the pyrometer!
Stay with the device and finish the
preheating and melting as described
manually!