48
4.2 Menu Keys
UNITEST Hexagon 330/340
Key is used to display the
following values: top or bottom
value, the difference between top
and bottom value of a measure-
ment series.
(Peak Hold)
This key is used to switch to the
CREST function (Peak Hold). This
function enables detection of
maximum and minimum values of
short signals (> 5 ms).
The key is used to switch to
the relative value function. Hereby,
the display can be set to zero to
determine the relative value for a
measurement value.
The key is used to magnify
the analogue bargraph display by
factor 5.
UNITEST Hexagon
310/320/330/340
Measurement ranges marked in
yellow on the function switch can
be selected via key . If this
key is pressed for longer than one
second the backlight is automati-
cally switched on.
Key is used to select bet-
ween automatic and manual mea-
surement ranges selection.
Key is used to switch to fre-
quency measurement range.
If the display cannot be seen
during the measurement or if the
value is fluctuating, the measure-
ment value can be frozen by pres-
sing the switch .