X2 series with embedded CODESYS control Recommendations and limitations
SUEN00392E 2022-03
55 (61)
Normal.dotm
, 2020-09-09
The xml file for iX Developer is created automaticly when you transfer the project or when
executing
Generate code
from Menu\Build in CODESYS.
The file is saved in same folder as the project.
It’s important to note that the variables that are selected in the Symbol Configuration also
decides which variables that can be externaly accessed, for example iX Developer or other
devices/hardware using ARTI protocol.
Therefore, the Symbol Configuration have to be downloaded to the Device each time it has
been changed and a new xml-file will be created. The iX Developer taglist also have to match
the Symbol Configuration in order to connect to the variables.
If you are trying to access a tag that is not available in the Symbol Configuration you will get
a controller error message in the iX HMI application.