11
BAC 5100yf Rev. A
Install the Oil Drain Bottle
1.Holdtheoildrainbottlestraight,andinsertthe
connectorintotheholeuntilitsnapsintoplace.See
Figure2.
Power Up the Machine
1.Unwindthepowercordfromthehandle,andplugit
intoacorrectvoltage,groundedoutlet.
2.Positionthemachinesotheplugandthemain
powerswitchareofeasyaccessfortheoperator.
Verifythefanventsontherearofthemachineare
notobstructed.
3.Lockthefrontwheels.
4.TurntheLockout/TagOutleverclockwise(CW)to
switchitON.
5.TurnONthemainpowerswitch.
Thersttimethemachineispoweredup,itdisplays
thelicenseagreementforyourapprovalandthen
launchesintotheinitial
Setup
mode.
Language Selection
Theoperatorselectsthelanguageforthescreen
promptdisplays.Englishisthedefaultlanguage.
1.
UsetheUPorDOWNarrowkeytotogglethroughthe
availablelanguages.
2.
PressOKtosettheselectedlanguage.
Unit of Measure
Theoperatorsetsthedisplayforunitsofmeasure.
Metricisthedefault.
1.UsetheUPorDOWNarrowkeytotogglekilograms
orpounds.
2.
PressOK tochoosethedisplayedunitofmeasure.
Setup
CAUTION: The machine is
programmed to run the setup
procedure as outlined here. To prevent
personal injury, do NOT operate the
machine without the oil ll port plug
installed, because the vacuum pump is
pressurized during normal operation.
Figure 2
Oil Drain
Bottle