Flushing the Hoses
Ifthenextvehicletobeservicedcontainsadifferent
typeofoilthanthepreviousvehicleserviced,itis
recommendedtheservicehosesbeushedofresidual
oiltopreventcontamination.
1.Connecttheservicehosestothemachine’sstorage
portconnections(showninFigure9).
2.Openthecouplervalvesbyturningthecollars
clockwise.
3.SelectHOSE FLUSHfromtheSetupMenu.The
machinedisplays
CONNECTBOTHSERVICEHOSES
TOSTORAGEPORTS
ANDOPENBOTHCOUPLERVALVES.
PRESSOKTOCONFIRM
4.SelectOK tobeginthehoseushprocess,which
runsforthreeminutes,followedbyarecovery.
5.Whenthehoseushingprocessiscompete,the
displayreads
HOSEFLUSHINGOK
PRESSOKTOCONFIRM
PressOKtoconrmthedisplaymessages.
6.Closethecouplervalvesbyturningthecollars
counterclockwise.
7.PressOK toreturntotheSetupMenu.