39
BAC 5100yf Rev. A
Troubleshooting Messages
Display Cause Solution
AIRFLOWERROR
Fanisnotworking.Airowis
blocked.
Exit current test and contact a
Beissbarth authorized service
center for repair.
ANALYZERERROR1
UNSTABLEOUTPUT
PossibleelectromagneticorRF
(radiofrequency)interference.
Move unit away from any EMF
or RFI sources.
ANALYZERERROR2
HIGHOUTPUT
PossibleelectromagneticorRF
(radiofrequency)interference.
Move unit away from any EMF
or RFI sources.
ANALYZERERROR3
AIRCALIBRATIONLOW
Possiblerefrigerantinexternal
calibrationair.
Check air ventilation and air
ow.
ANALYZERERROR4
IDENTIFIEROUTOF
TEMPERATURERANGE
Identiertemperatureoutof
operatingrange.
Check unit ventilation and
ambient conditions.
ANALYZERERROR5
REPLACEIDENTIFIER
FILTERANDSAMPLEHOSE
ASSEMBLY
Samplehoseorlterinsidethe
refrigerantidentierispossibly
pluggedorcontaminatedwith
oil.
Follow maintenance procedure
to change identier lter and
sample hose.
CHARGEINPROGRESS
AIRPURGE
Non-condensablegasis
presentinISVthatcould
contaminateA/Csystem.
Before it charges, the machine
purges air out of the ISV.
CHECKOILBOTTLE
1)AfterselectingINJECT OIL,
oilinjectbottleisnotincorrect
position.
2)AfterselectingINJECT OIL,
thereisaninsufcientamount
ofnewoilinoilinjectbottle
1) Verify the oil inject bottle is
attached to the machine as
explained in the Setup section.
2) Fill the oil inject bottle with
new oil as explained in the
Setup section.
INSUFFICIENTPRESSURE
Ifpressureislessthan
0.7bar,therefrigerantcannot
beidentied.
Refer to Vacuum section and
follow instructions to evacuate
the system.
ISVCONDITION
Machineiscirculating
refrigeranttobuildISVpressure
forachargecycle.
The charge process is
automatically interrupted and
the machine operates in a
mode to build tank pressure.
Once tank pressure is sufcient,
the machine automatically
completes the charge.
PRESSUREDECAYTEST
FAILED
AleakinthevehicleA/C
system.
Exit current test and perform
repairs on the vehicle A/C
system.