EasyManua.ls Logo

Beissbarth BAC 5100yf - Messages

Beissbarth BAC 5100yf
51 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
39
BAC 5100yf Rev. A
Troubleshooting Messages
Display Cause Solution
AIRFLOWERROR
Fanisnotworking.Airowis
blocked.
Exit current test and contact a
Beissbarth authorized service
center for repair.
ANALYZERERROR1
UNSTABLEOUTPUT
PossibleelectromagneticorRF
(radiofrequency)interference.
Move unit away from any EMF
or RFI sources.
ANALYZERERROR2
HIGHOUTPUT
PossibleelectromagneticorRF
(radiofrequency)interference.
Move unit away from any EMF
or RFI sources.
ANALYZERERROR3
AIRCALIBRATIONLOW
Possiblerefrigerantinexternal
calibrationair.
Check air ventilation and air
ow.
ANALYZERERROR4
IDENTIFIEROUTOF
TEMPERATURERANGE
Identiertemperatureoutof
operatingrange.
Check unit ventilation and
ambient conditions.
ANALYZERERROR5
REPLACEIDENTIFIER
FILTERANDSAMPLEHOSE
ASSEMBLY
Samplehoseorlterinsidethe
refrigerantidentierispossibly
pluggedorcontaminatedwith
oil.
Follow maintenance procedure
to change identier lter and
sample hose.
CHARGEINPROGRESS
AIRPURGE
Non-condensablegasis
presentinISVthatcould
contaminateA/Csystem.
Before it charges, the machine
purges air out of the ISV.
CHECKOILBOTTLE
1)AfterselectingINJECT OIL,
oilinjectbottleisnotincorrect
position.
2)AfterselectingINJECT OIL,
thereisaninsufcientamount
ofnewoilinoilinjectbottle
1) Verify the oil inject bottle is
attached to the machine as
explained in the Setup section.
2) Fill the oil inject bottle with
new oil as explained in the
Setup section.
INSUFFICIENTPRESSURE
Ifpressureislessthan
0.7bar,therefrigerantcannot
beidentied.
Refer to Vacuum section and
follow instructions to evacuate
the system.
ISVCONDITION
Machineiscirculating
refrigeranttobuildISVpressure
forachargecycle.
The charge process is
automatically interrupted and
the machine operates in a
mode to build tank pressure.
Once tank pressure is sufcient,
the machine automatically
completes the charge.
PRESSUREDECAYTEST
FAILED
AleakinthevehicleA/C
system.
Exit current test and perform
repairs on the vehicle A/C
system.