BAC 5100yf Rev. A
Maintenance
Figure 23
Oil Inject
Bottle 2
(greencolor
oncover)
Oil Inject
Bottle 1
(whitecover)
UV Dye
Inject Bottle
(yellowcolor
oncover)
Magnetic Couplers
Calibrate Oil and Dye Inject Scales
1.Removethedyeinjectandoilinjectbottlesfrom
theirscales.SeeFigure23.
2.SelectCALIBRATE OIL INJECT 1fromtheSetup
menu.
3.Whenpromptedfortherstweight,accept
0GRAMS
asthedefault,andpressOK.
4.Whenpromptedforthesecondweight,attachthe
calibrationweightsuppliedwiththemachinetothe
magneticconnectorfortheOilInject1scale.
5.Program
533GRAMS
andpressOK.
6.Whenpromptedthatthecalibrationiscomplete,
pressOKtoexit.
7.Repeatthisprocedurefortheothertwoloadscales
byselectingCALIBRATE OIL INJECT 2and
CALIBRATE UV DYE INJECTfromSetupmenu.
Calibrate Oil Drain Scale
1.Removetheoildrainbottlefromthescale.
2.Hookthenotchintheendoftheoildraincalibration
bracket(supplied)aroundtheoildraininletttingas
showninFigure24.
3.SelectCALIBRATE OIL DRAINfromtheSetup
menu.
4.Whenpromptedfortherstweight,enter
53GRAMS
asthedefault,andpressOK.
5.Whenpromptedforthesecondweight,placethe
calibrationweightsuppliedwiththeunitonthe
bracketasshown,andenterthefollowingvalue:
586GRAMS
6.Whenpromptedthatthecalibrationiscomplete,
pressOKtoexit.
7.Removethecalibrationweightandbracket,and
replacetheoildrainbottle.
Figure 24
Oil Drain
Calibration
Bracket and
Weight
Oil Drain
Inlet Fitting