35
BAC 5100yf Rev. A
Maintenance
Figure 23
Oil Inject
Bottle 2
(greencolor
oncover)
Oil Inject
Bottle 1
(whitecover)
UV Dye
Inject Bottle
(yellowcolor
oncover)
Magnetic Couplers
Calibrate Oil and Dye Inject Scales
1.Removethedyeinjectandoilinjectbottlesfrom
theirscales.SeeFigure23.
2.SelectCALIBRATE OIL INJECT 1fromtheSetup
menu.
3.Whenpromptedfortherstweight,accept
0GRAMS
asthedefault,andpressOK.
4.Whenpromptedforthesecondweight,attachthe
calibrationweightsuppliedwiththemachinetothe
magneticconnectorfortheOilInject1scale.
5.Program
533GRAMS
andpressOK.
6.Whenpromptedthatthecalibrationiscomplete,
pressOKtoexit.
7.Repeatthisprocedurefortheothertwoloadscales
byselectingCALIBRATE OIL INJECT 2and
CALIBRATE UV DYE INJECTfromSetupmenu.
Calibrate Oil Drain Scale
1.Removetheoildrainbottlefromthescale.
2.Hookthenotchintheendoftheoildraincalibration
bracket(supplied)aroundtheoildraininletttingas
showninFigure24.
3.SelectCALIBRATE OIL DRAINfromtheSetup
menu.
4.Whenpromptedfortherstweight,enter
53GRAMS
asthedefault,andpressOK.
5.Whenpromptedforthesecondweight,placethe
calibrationweightsuppliedwiththeunitonthe
bracketasshown,andenterthefollowingvalue:
586GRAMS
6.Whenpromptedthatthecalibrationiscomplete,
pressOKtoexit.
7.Removethecalibrationweightandbracket,and
replacetheoildrainbottle.
Figure 24
Oil Drain
Calibration
Bracket and
Weight
Oil Drain
Inlet Fitting