45
BAC 5100yf Rev. A
Charge Function
Thechargeprocessincludesapre-chargeleaktest
thatllsthesystemwithasmallamountofrefrigerant
andthenmonitorspressuredecay.
—If the leak test passes,therefrigerantis
automaticallyrecoveredandtheselectedchargeis
added.
—If the leak test fails
,therefrigerantneedstobe
recoveredandthevehicleneedstobecheckedfor
leaksbyusinganelectronicleakdetector.
Troubleshooting Procedures
System Flush
Display Message: NO FLOW DETECTED
Iftheexternalushinglterisplugged,themachine
displays
POSSIBLECLOGGEDFLUSHFILTER
PRESSOKTOREPLACE
PRESSESCTOABORT
Themessagerepeatsuntilthelterisreplaced.