37
WILL NOT RAISE LOADED LIFT
POSSIBLE CAUSE
1. Air in oil, (1,2,3,4)
2. Cylinder binding, (5)
3. Cylinder leaks internally, (5)
4. Lift overloaded, (6,5)
5. Lowering valve leaks, (7,8,1,5,9)
6. Motor runs backwards, (10,12,9)
7. Pump damaged, (5,9)
8. Pump won’t prime, (1,2,3,4,5,11,9)
9. Relief valve leaks, (8,5,9)
10. Voltage to motor incorrect, (10,12,5)
REMEDY INSTRUCTION
1. Check oil level The oil level should be up to the bleed screw in the reservoir
with the lift all the way down.
2. Check/Tighten inlet tubes Replace inlet hose assembly.
3. Oil seal damaged or cocked Replace oil seal and install
4. Bleed cylinders See Installation Manual
5. See Installation Manual Consult Lift Manufacturer
6. Check vehicle weight Compare weight of vehicle to weight limit of the lift.
7. Flush release valve Hold release handle down and start unit allowing it to run for 15
seconds.
8. Replace with new part Replace with new part
9. Return unit for repair Return unit for repair
10. Check motor is wired correctly Compare wiring of motor to electrical diagram on unit drawing
11. Inlet screen clogged Clean inlet screen or replace.
12. Check wall outlet voltage and wiring Make sure unit and wall outlet is wired properly.