PROGRAMMING
The programming of the various functions of the control unit is carried out using the LCD display on the control unit and
setting the desired values in the programming menus described below.
The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer.
The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch.
Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or the
software release.
USE OF PROGRAMMING KEYS
Press <PG> key to gain access to the Main Menu (PAR>>LOG>>RADIO>>...). These keys can be selected by pressing +
and – keys.
Select the Main menu with <PG> key to enter the desired Function Menu .
• If <+> is pressed, the Function Menu can be scrolled from top to bottom.
• If <-> is pressed, the Function Menu can be scrolled from bottom to top.
• If <PG> key is pressed, presetting to be modied can be entered.
• The preset values can be modied by using <+> and <-> keys.
• The value is programmed if <PG> key is pressed again. The word “PRG” appears on the display.
See paragraph “Programming Example”.
NOTES:
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without mak-
ing any changes.
A pressure of the push-button <-> with display off equals a Step-by-Step control signal.
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 30s the control unit quits programming mode and switches off the display.
Pressing <-> with the display turned off means an impulse of P.P.
PARAMETERS, LOGICS AND SPECIAL FUNCTIONS
In the tables hereunder the single functions available in the control unit are shown.
MENU FUNCTION
MIN-MAX-(Default)
MEMO
PARAMETERS
TCA
Automatic closure time. Active with logic “TCA”= ON only.
At the end of the preset time, the control unit sends a closure control
signal.
1-240-(40s)
Tped
The stroke time of the gate leaf is adjusted during the partial opening
phase controlled by the pedestrian input.
5-100-(20%)
TSM
The gate leaf stroke during the braking phase is adjusted. 5-100-(20%)
PMo
The anti-crash device* (amperometric sensor) operation is adjusted in the
opening phase, at normal speed.
1: maximum sensitivity - 99:minimum sensitivity.
1-99-(25%)
PMC
The anti-crash device* (amperometric sensor) operation is adjusted in the
closing phase, at normal speed.
1: maximum sensitivity - 99:minimum sensitivity.
1-99-(25%)
PSo
The anti-crash device* (amperometric sensor) operation is adjusted in the
opening phase, at reduced speed.
1: maximum sensitivity - 99:minimum sensitivity.
1-99-(25%)
PSC
The anti-crash device* (amperometric sensor) operation is adjusted in the
closing phase, at reduced speed.
1: maximum sensitivity - 99:minimum sensitivity.
1-99-(25%)
TLS
It is activated only with SERL logics: ON.
The activation time of the service light is adjusted. If lamps with a voltage
higher than 24VDC and 1A max current are used, use the auxiliary relay
(see Fig. 1).
1-240-(60s)
* WARNING:
An incorrect setting of these parameters may cause danger.
Please comply with regulations in force!