27
EN
BAR Sensing safety edge
Sensing edge contact input
Resistive safety edge (8K2): JP1 "BAR" closed
Mechanical safety edge (N.C.): JP1 "BAR" open
The intervention of the safety edge stops the movement of the gate and reverses for approximately 3s.
RADIO Radio receiver
Quick connector for external radio receiver mod. ONE.2WI, use in wiring supplied, see figure 18.
2CH Second channel N.O. output of the second radio channel of the radio receiver. (max 24Vac/dc 1A)
BRAKE Brake Resistance Input for braking current dissipation resistance
P3 Not used
COM1 Not used
J7 Not used
J8 Not used
SW1 Dip1, Dip2 Keep it ON
U1
CONFIGURATION
MEMORY
E-Eprom extractable memory. it contains all the configurations of the unit (logical, parameters, etc.),
excluding radio transmitters. In case of failure it is possible to extract the E-Eprom and insert it in a
different unit, thus avoiding reprogramming.
LD1 High voltage Led Led indicating HIGH VOLTAGE
LD2 Low voltage Led Led indicating LOW VOLTAGE
9.2) HOW TO CHECK CONNECTIONS
1) Cut off power supply.
2) Manually release the door/gate and push it for about half stoke. Lock the door again.
3) Restore power supply.
4) Send a step-by-step command through push-button <-> on the control unit (LCD display off). To stop the door/gate press <-> once more.
5) The door/gate should open. If not, set the MINV logics to change the opening direction (default MINV=OFF) Engine installed to the left.
10) PROGRAMMING
The programming of the various functions of the control unit is carried out using the LCD display on the control unit and setting the desired values in
the programming menus described below.
The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer.
The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch.
Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or the software release.
11) TO ACCESS PROGRAMMING
1 - Press the button <PG>, the display goes to the first menu, Parameters “PAR”.
2 - With the <+> or <-> button, select the menu you want.
3 - Press the button <PG>, the display shows the first function available on the menu.
4 - With the <+> or <-> button, select the function you want.
5 - Press the button <PG>, the display shows the value currently set for the function selected.
6 - With the <+> or <-> button, select the value you intend to assign to the function.
7 - Press the button <PG>, the display shows the signal “PRG” which indicates that programming has been completed.
11.1) RUN SELF-LEARNING AND ANTI-CRUSHING DEVICE SETTING
When operator assembly and wiring is completed, parameters and logic are programmed, self learning allows the operator to learn the stroke and torque.
Enter menu Auto and press the button < PG >, PUSH will be displayed.
Press again the button < PG >: self-learning is beginning: PRG will be displayed, and the control panel completes some opening/closing cycles.
When the procedure is completed OK will be displayed.
This procedure can be followed from any position of the gate/door leaf and can be stopped at any moment by pressing keys <+> and <-> at the same
time, or through the activation of STOP/PHOTO/PHOTC/PHA/BAR/PP/PED inputs.
If the procedure is not successful, the wording ERR appears. Check that no obstacles or frictions are present.
After the AUTOSET procedure it is necessary to check the value of the operating forces according to the European Standards EN12445 and EN12453.
If the value of the force is too high it is mandatory to install a safety edge which complies to the standard EN12978.
Check the value of the operative forces in accordance with EN12445 and EN12453 at the end of the autoset phase. If the value of the force is too high
install an edge compliant with EN12978.
Notes:
Pressing <-> with the display turned off means an impulse of P.P.
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without making any changes.
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 30s the control unit quits programming mode and switches off the display.
12) PARAMETERS, LOGIC AND SPECIAL FUNCTIONS
The tables below describe the individual functions available in the control unit.
PARAMETERS (PAR)
MENU FUNCTION MIN-MAX-(Default) MEMO
TCA
Automatic closure time. It is activated only with “TCA” logics :ON
At the end of the preset time, the control unit starts a new closing operation.
1-240-(40s)
Tped
The passage left open by the door/gate leaf during the partial opening controlled by the
pedestrian inoput, is adjusted.
The value is expressed in percentage on the aggregate value of the stroke.
5-100-(20%)