Maintenance
Indicators
POWER TEMP
LIGHT
SOURCE
STATUS
System Messages
O
Stand-by
G
Powering up
G
Normal operation
O
Normal power-down cooling
R
R
R
Download
G
R
CW start fail
G
R
Phosphor Wheel start fail
O
R
Case open
O
G
Thermal break sensor error
Burn-In Messages
G
Burn-in on
G
G
G
Burn-in off
Light source Error Messages
R
Light source 1 error in normal operation
R
Light source is not lit up
Thermal Error Messages
R
R
Fan 1 error (the actual fan speed is outside the desired speed)
R
R
Fan 2 error (the actual fan speed is outside the desired speed)
G
R
Temperature 1 error (over limited temperature)
G
R
Thermal Sensor 1 open error
G
G
Thermal Sensor 1 short error
G
G
Thermal IC #1 I2C Connection error
G
R
Temperature 2 error (over limited temperature)
G
R
Thermal Sensor 2 open error
G
G
Thermal Sensor 2 short error
G
G
Thermal IC #2 I2C Connection error
G
R
R
Temperature 3 error (over limited temperature)
G
R
R
Thermal Sensor 3 open error
G
R
G
Thermal Sensor 3 short error
G
R
G
Thermal IC #3 I2C Connection error
O
:
Static orange
O
:
Flashing orange (cycle : on 1 sec/off 1 sec)
G
:
Static green
G
:
Flashing green (cycle : on 1 sec/off 1 sec)
R
:
Static red
R
:
Flashing red (cycle : on 1 sec/off 1 sec)