EasyManua.ls Logo

Bentel Security B3G-220 - USB Firmware Update and Settings Export

Bentel Security B3G-220
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
58 Universal Cellular Communicator
SSSSSSSS represents the communicator's serial number (8 hex digits), so that a single USB key can hold data for several different
communicators: each communicator will read/write to its own folder.
When a USB key is inserted into the communicator, the following procedure is executed:
1. Firmware update, if a valid firmware is in folder B_FW;
2. Communicator settings file export, if the file export.txt is in folder B_PROG;
3. Communicator settings file import, if the file import.txt is in folder B_PROG;
4. Communicator voice message export, if the file export.txt is in folder B_AUDIO;
5. Communicator voice message import, if the file import.txt is in folder B_AUDIO;
6. Communicator event buffer export, if the file log.txt is in folder B_LOG;
Firmware Update
This operation updates the communicator's firmware from a USB key.
1. Download the firmware from the site www.bentelsecurity.com.
The name of the firmware file has the format FWxxyyzz.bin where:
FW identifies the file as firmware;
xx is the higher revision number;
yy is the lower revision number;
zz is the test revision number;
.bin is the extension for a binary file.
DO NOT rename the firmware file, otherwise the communicator will not recognise it.
2. Copy the firmware into folder B_FW on the USB key.
3. Insert the key into the communicator's USB port.
If the communicator finds an invalid firmware in folder B_FW, the ACT LED will flash slowly and the event Firmware Upgrade
failed - System is logged to the event buffer.
If the communicator finds a valid firmware in folder B_FW, which is also different from its current firmware, it will install it.
If more than one firmware file is in folder B_FW, the communicator will install the one with the highest revision number.
If folder B_FW contains a firmware which is less recent than the current one installed on the Communicator, it is installed
anyway: firmware updates allow you to install a more recent firmware or restore an older one than currently installed on the
communicator.
At the end of the process the communicator reboots and logs the event FW upgrade done - System.
in the event buffer.
Exporting settings
This operation exports the communicator's settings to a USB key.
1. Create the folder B_PROG on the USB key, if it is not already there.
2. Create a new text file in folder B_PROG and call it export.txt.
3. Insert the USB key into the communicator's USB port.
The communicator will export its settings to B_PROG\SSSSSSSS\EXPORT\eprognnn.bin, where:
SSSSSSSS is the communicator's serial number;
eprog is the prefix for a communicator settings file;
nnn is an index from 001 to 999;
.bin is the extension for a binary file.
The communicator will search the EXPORT folder for the settings file with the highest index and create a settings file with that index