26
Bentone
6.1.3 Replacement of pump  lter
1. Close the oil supply to the burner.
2. Loosen the pump cover’s screws.
3. Remove the  lter and gasket.
4. Mount new gasket and  lter.
5. Re t the cover.
6. Open the oil supply.
7. Start the burner, check seals and combustion.
!
Usecautionwhenoperatingtheburner,surfacesmaybehot.
!
Whenservicingoilbearingcomponents,checkforoilleakage
when the burner are put into operation.
Filter
Gasket
6.1.2 Check oil line seals
When the burner has been installed and put into operation, the tightness
of the various coupling elements should be checked (A), in case of leakage -
retighten the coupling elements.
!
Whenservicing/replacingcomponentsthataectcombustion,
uegasanalysisandsoottestmustbecarriedoutfollowing
installation.

Related product manuals