178 000 82
Installation- and maintenance instruction
BG550,BG550LN,BG650

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Bentone BG600 and is the answer not in the manual?

Bentone BG600 Specifications

General IconGeneral
BrandBentone
ModelBG600
CategoryBurner
LanguageEnglish

Summary

DESCRIPTION

Warning

Safety warnings and precautions for installation and operation.

Safety directions

Electrical safety, cable management, and interlocks for safe operation.

TECHNICAL DATA

Output range

Gas volume, inlet pressure, and output capacity for different models.

Working field

Graphical representation of burner performance limits based on capacity.

SKELETON DIAGRAMS

ELECTRIC EQUIPMENT

Wiring diagram LGB22/LMG22/LME22 (BG550/BG650) 2-Stage

Electrical schematic for the 2-stage LGB22/LMG22/LME22 control.

List of components LGB22/LMG22/LME22 (BG550/BG650) 2-Stage

Component identification for the 2-stage LGB22/LMG22/LME22 wiring diagram.

Function LGB22/LMG22/LME22

Step-by-step operational sequence for the LGB22/LMG22/LME22 control.

Wiring diagram LMG22/LME22 (BG550/BG550LN/BG650) Modulating

Electrical schematic for the modulating LMG22/LME22 control.

List of components LMG22/LME22 (BG550/BG550LN/BG650) Modulating

Component identification for the modulating LMG22/LME22 wiring diagram.

Function LMG22/LME22

Step-by-step operational sequence for the modulating LMG22/LME22 control.

Wiring diagram LMG22 (BG550/BG550LN/BG650) Modulating with R316

Electrical schematic for the LMG22 modulating control with R316.

List of components LMG22 (BG550/BG550LN/BG650) Modulating with R316

Component identification for the LMG22 modulating with R316 wiring diagram.

Function LMG22

Operational sequence for the LMG22 modulating control.

Control program when disruption; disruption display Gas burner control: LME....

Diagnostic codes and sequences for LME burner control disruptions.

Wiring diagram LFL1... (BG550/BG550LN/BG650) Modulating

Electrical schematic for the modulating LFL1 burner control.

List of components LFL1... (BG550/BG550LN/BG650) Modulating

Component identification for the modulating LFL1 wiring diagram.

Wiring diagram LFL1... (BG550/BG550LN/BG650) Modulating with R316

Electrical schematic for the LFL1 modulating control with R316.

Wiring diagram LFL1... (BG550/BG650) 2-Stage

Electrical schematic for the 2-stage LFL1 burner control (reiteration).

List of components LFL1... (BG550/BG650) 2-Stage

Component identification for the 2-stage LFL1 wiring diagram (reiteration).

Function LFL1...

Operational sequence for the LFL1 burner control (reiteration).

Control programme under fault conditions and lockout indication LFL1....

Troubleshooting guide for LFL1 control fault conditions.

MEASURES AND CHECKS BEFORE START-UP

DETERMINATION OF GAS VOLUME FOR THE INSTALLATION

GAS SOLENOID VALVE MVD

OPERATION AND ASSEMBLY INSTRUCTIONS

MULTI-BLOC, MB-ZRDLE 405 - 420 B01

MULTI-BLOC, MB-VEF 412 - 425 B01

GENERAL INSTRUCTIONS

GENERAL INSTRUCTION

Flame monitoring and measurement of ionisation current

Principles of flame detection and measuring ionization current.

LEAKAGE CONTROL, DUNGS VPS 504 SERIES 2

HANDING OVER OF THE INSTALLATION

Fault location, functional troubles

Guide to identifying and resolving common operational issues and faults.