57
caldaie
CIAO C.A.I. - C.S.I.
Error signal inspection:
sanitary or heating proble failure
NO
NO
NO
YES
GREEN LED OFF
RED LED FLASHING
YELLOW LED OFF
SANITARY OR
HEATING PROBE
FAILURE
BOILER
WORKING ON
HEATING
CHECK
SANITARY PROBE GAUGING
See section 1.5.13
page 6
REPLACE PROBE
see table 4.4.10 page 33
and table 4.4.11 page 34
ADEQUATE
WIRING AND CONNECTIONS
BETWEEN SANITARY PROBE AND THE
ELECTRONIC CONTROL BOARD
see APPENDIX - E
pages 81-82
ADJUST THEM
see APPENDIX - E pages 81-82
REPLACE THE ELECTRONIC
CONTROL BOARD
see table 4.4.9 page 32
CHECK
HEATING AND
SANITARY PROBE GAUGING
See section 1.5.13
page 6
ADEQUATE
WIRING AND CONNECTIONS
BETWEEN HEATING AND
SANITARY PROBE AND THE
ELECTRONIC CONTROL BOARD
see APPENDIX - E
pages 81-82
YES
YES
YES
YES
LED YELLOW
LED GREEN
LED RED