62
caldaie
CIAO C.A.I.
Fumes thermostat and limit thermostat inspection
LED YELLOW
LED GREEN
LED RED
NO
NO
NO
NO
NO
NO
YES
FUMES THERMOSTAT-
LIMIT THERMOSTAT
INSPECTION
REPLACE THE ELECTRONIC
CONTROL BOARD
See table 4.4.9 page 32
REPLACE ELECTRONIC
CONTROL BOARD
See table 4.4.9 page 32
CONTINUITY ON
FUMES THERMOSTAT
TERMINALS
See appendix - E
pages 81-82
CHECK WORKING CONDITION
OF FUMES THERMOSTAT
see table 4.4.12 page 35
AND FUMES EXHAUST
see appendix - C page 78
CORRECT
WIRING AND
CONNECTIONS TO
FUMES THERMOSTAT
See appendix - E
pages 81-82
ADJUST THEM
See appendix - E pages 81-82
CHECK WORKING
CONDITIONS OF LIMIT
See table 4.4.13 page 36
CIRCUIT CH
AND WATER CIRCULATION
See section 1.5.15 page 6
THERE ARE
230 VAC BETWEEN
TERMINALS M1.26 AND M1.27
ON THE ELECTRONIC
CONTROL BOARD
See appendix - E
pages 81-82
CONTINUITY ON LIMIT
THERMOSTAT TERMINALS
See appendix - E
pages 81-82
CORRECT
WIRING AND
CONNECTIONS TO LIMIT
THERMOSTAT
See appendix - E
pages 81-82
THERE ARE
230 VAC BETWEEN
TERMINALS M1.27 AND M1.28
ON THE ELECTRONIC
CONTROL BOARD
See appendix - E
pages 81-82
YES
YES
YES
YES
YES
REPLACE THE ELECTRONIC
CONTROL BOARD
See table 4.4.9 page 32
ADJUST THEM
See appendix - E pages 81-82