1.7 Technical specications
Description
POWER MAX
U.M.
50 P
DEP
50 P 65 P 80 P 100 110 130 150
Appliance type
Condensing boiler heating system
B23; B53; B53P; C13*; C33*; C53*; C63*
Fuel - Device category
IT-GB-GR-IE-PT-SI: G20=20mbar G30/G31=28-30/37mbar; II2H3+
SK: G20=20mbar G30=28-30mbar G31=37mbar; II2H3+
ES: G20=18mbar G30=28-30mbar G31=37mbar; II2H3+
BE: G20/25=20/25mbar; I2E(S)
BE: G30/G31=28-30 /37mbar G31=28-30/37mbar; I3+
MT-CY-IS: G30=30mbar; I3B/P
FR: G20/G25= 20/25mbar G30/G31=28-30/37mbar; II2E+3+
PL-RU: G20=20 mbar G30= 37 mbar (RU=37mbar); II2E3B/P
LU: G20=20 mbar G31=37 mbar; I2E3P
DE: G20/G25=20 mbar G30=50 mbar; II2ELL3B/P
PL: G20=20mbar G30/G31=30mbar; II2ELwLs3P
FR: G20/G25=20/25 mbar G30/G31=28-30/37mbar; II2ESi3+
FR: G20/G25= 20/25mbar G30=28-30mbar; II2ESi3B/P
RO-IE-SI-BG-DK-SK-EE: G20=20mbar G30=30mbar; II2H3B/P
SE-NO-LV-LT-FI-TR: G20=20mbar G30=30mbar; II2H3B/P
HR: G20=20mbar G30/G31=30mbar; II2H3B/P
HU: G20=25mbar G30=30mbar; II2H3B/P
SK-CZ-LU-AT-CH: G20=20mbar G30=50mbar; II2H3B/P
SI-SK: G20=20mbar G31=37mbar; II2H3P
NL: G25=25mbar G30=30mbar; II2L3B/P
Combustion chamber vertical
Maximum rated heat input at furnace
referred to HVC (LCV)
38,7
(34,9)
50P
(45)
63
(57)
76
(68)
100
(90)
108
(97)
124
(112)
146
(131)
kW
Minimum rated heat input at furnace
referred to HVC (LCV)
10
(9)
10
(9)
15
(14)
15
(14)
21,6
(19,4)
21,6
(19,4)
24,9
(22,4)
29,2
(26,2)
kW
Useful (rated) heat output 34,4 44,2 56 68 88 95 110 129 kW
Maximum rated heat
output (80-60°C)
P4 G20 34,4 44,2 55,7 67,0 88,3 95,3 109,8 129,0 kW
Maximum nominal heat
output (60-40°C)
- G20 36,6 47,0 59,6 71,4 93,8 101,1 116,2 137,3 kW
30% heat output with
return at 30°C
P1 G20 11,5 14,7 18,7 22,3 29,4 31,7 36,6 43,0 kW
Minimum rated heat
output (80-60°C)
- G20 8,9 8,9 13,5 13,5 19,2 19,2 22,1 26 kW
Efciency class in central heating
mode
A A A A - - - -
Seasonal energy ef
-
ciency in central heating
mode
ηs
94 94 94 94 94 94 94 94 %
Efciency at rated heat
input and High tempera-
ture GCV (NCV) regime
η4
useful
Pn
(60-
80°C)
88,9
(98.6)
88,4
(98.2)
88,4
(97.7)
88,2
(98.5)
88,3
(98.1)
88,2
(98.2)
88,5
(98,0)
88,4
(98.5)
%
Efciency at 30% of the
nominal thermal ow
and on low PCS temper-
ature regime
η1
useful
30%
of Pn
98,4
(109,5)
98,2
(109,2)
98,2
(109,2)
98
(108,8)
98,1
(108,9)
98
(108,8)
98
(108,8)
98,1
(108,9)
%
Chimney losses with burner on at max.
Pn (80-60°C)
2,3 2,3 2,3 2,3 2,5 2,6 2,5 2,6 %
Chimney losses with burner on at max.
30% Pn (50-30°C)
0,5 0,5 0,5 0,5 0,6 0,6 0,5 0,6 %
Heat loss in standby
mode
Pstby
45 57 72 87 115 124 143 168 W
0,1 %
Annual energy con-
sumption
QHE 71 91 117 141 - - - - GJ
Noise level (sound
power)
LWA
at P
max
51 52 53 54 55 56 57 57 dB(A)
Emissions (**) NOx
(re-
ferred
to
HCV)
42,0
43,9 34,2 36,4 38,1 38,7 39,3 46,1
mg/
kWh
Emissions at max./min.
heat input, G20
CO
2
9 - 9 (*****) %
CO 63/2,3 73/2,3 79/6,5 90/6,5 81/7,5 91,5/7,5 89/4,6 91,5/5,6 ppm
Maximum rated heat
input (LCV)
G25 34,9 45 53 65 85 93 107 127 kW
Minimum rated heat
input (LCV)
G25 9 9 13 13 18,1 18,5 21,4 24,5 kW