touch sensitivity of the lip sensor is divided into the number of steps added.
Values from 1 to 6. Default OFF.
SETUP CTR – HARM SEL
The harmonic series can be set up in a number of ways, going both up
(best option for using the lip sensor) or down (useful for example with a custom
experimental mouthpiece sensing amount of lip pressed against it).
HM1 – Harmonics 1
HM2 – Harmonics 2 (7th harmonic not excluded)
5TH – 5ths and octaves, up
OCT – Octaves, up
H1R – Harmonics 1, down/reverse
H2R – Harmonics 2 (7th harmonic not excluded), down/reverse
5TR – 5ths and octaves, down/reverse
OCR – Octaves, down/reverse
SETUP CTR - DEGLITCH
To reduce glitching when fingerings are changed, the deglitching function
waits some milliseconds before considering a fingering “done” and settled.
Beginners will probably feel the need to increase the deglitch setting, while
virtuoso players could feel the need to reduce the setting.
OFF – Deglitching disabled
1 ms – Lowest deglitch setting
..
20 ms (factory default)