Optional Heater controlled by the
Phoenix controller.
WARNING: If you have an Espar fuel
operated heater that was installed at the
factory or prior to the Phoenix install, you
can continue to operate the heater with the
existing controller. IF you choose to wire
the existing factory installed heater to the
Phoenix controller, YOU WILL VOID
THE FACTORY WARRANTY OF
THE HEATER!
Attach Espar Heater Control
Harness to Phoenix Unit
Espar control harness terminates the
same as when using the Espar mini
controller. Connector kit for the control
harness is included in the heater kit.
Route the control cable along the bed
towards the heater control panel. Use
zip ties as needed. Strip off 6″ of black
outer jacket from cable coming from
heater. Fold all wires back and cut off
the outer jacket, the blue, solid gray and
solid brown wires. Save the brown
wire and make a jumper wire. Strip
down ends of solid brown wire.
Connect one end of solid brown jumper
to brown/white wire. Add clips to ends
of wires and crimp on with crimper. On
connector, the numbers 1, 3, and 5 are
on one side, 2, 4, and 6 are on the other.
Insert wires into plug as follows: 1 = red,
2 = yellow, 3 = other end of jumper
including brown/white wire,
4 = gray with red stripe, 5 = brown jumper.
Now connect the heater control harness
to the Phoenix unit as shown in photo.