82527 Vantage34
5.1 PRACTICAL GUIDANCE
Regular cleaning:
By cleaning your machine regularly during and at the
end of the spraying season:
you will avoid spreading phytosanitary residues on
the crops,
you will ensure the product is evenly distributed by
preventing total or partial blockage of the nozzles,
you will increase the life span of your crop sprayer.
Formation of foam in the tank
If this happens, reduce the engine speed to less than
540 rpm or add an anti-foam additive to the contents
of the tank when lling.
Last lling:
When you ll the tank for the last time, only add the
quantity of water and product required to spray the
remaining surface of the eld.
End-of-spraying maintenance:
WARNING:
Carry out maintenance operations on
your crop sprayer with the tractor's
engine off, ignition stopped and the
power take-off disconnected.
IMPORTANT:
Do not add fuel-oil to the spray mixture as
an anti-foaming agent.
i
5. CROP SPRAYER MAINTENANCE
5.2 FILTERS
Suction lter:
The suction lter (1) is located at the control station.
To clean the lter cartridge, you must place the indexes
and the valves on the function
9
of BERLOGIC in
DUALMATIC or the function in DUALELEC.
To remove the lter cartridge, unscrew the nut (2) on
the lter.
Mesh of 10/10 for the use of liquid fertilisers and
concentrated spray mixtures.
Discharge lter:
The discharge lter (3) is located at the rear of the
machine, after the main tank.
It provides additional ltering.
To clean the filter cartridge, you must
place the indexes and the valves on the
function
9
of BERLOGIC in DUALMATIC or the
function in DUALELEC.
To remove the lter cartridge, unscrew the nut (4) on
the lter, using a size 27 spanner (not provided with
the machine).
Mesh of 8/10 for the use of liquid fertilisers.
IMPORTANT:
The lter cartridge should be cleaned after
each use. Grease the seals.
i
51
1
2
52
3
4
The machine should be fully internally rinsed (tanks,
booms and nozzles included) by following the
procedures ( 4.6).
Wash the exterior of the sprayer (
4.7).
Check the cleanliness of the nozzles and lters (
5.7).
Proceed with storage.