Note
For the delivery of a liquid with density that
differs from water and/or kinematic viscosity,
the delivery output is reduced.
Domestic hot water:
Permissible water hardness: max. 35°fH (20 °dH)
(water temperature below 65°C)
max. 25 °fH (14°dH)
(water temperature below 85°C)
To counter the risk of lime deposits, for domestic
hot water systems we recommend:
Hardness level max. 25°fH (14 °dH)
Medium temperature <65°C
Warning
The pump may not be used to deliver
combustible media such as diesel and fuel.
Warning
The pump may not be used to deliver
aggressive liquids such as acids or seawater.
Single pump Dual pump
ModulA… ModulA-D …
At 75 °C water temperature 0,10 bar 0,90 bar
At 95 °C water temperature 0,35 bar 1,20 bar
At 110 °C water temperature 0,65 bar 1,50 bar
Per ±100 m height ±0,01 bar ±0,01 bar
3.3 Operating conditions
Medium temperature:
ModulA RED +15 °C to +110°C
ModulA GREEN –10 °C to +110°C
ModulA BLUE +15 °C to +85 °C
(recommended for domestic
hot water systems: max 65 °C)
Operating pressure:
The maximum permissible operating pressure is indicated
on the nameplate. (6 bar, 10 bar or 16 bar)
Minimum operating pressure at the pump intake ports
(intake pressure ) at 500 m above sea level:
Ambient temperature:
0 °C to 40°C