11. Technical data
Supply voltage 1×230 V ±10%, 50/60 Hz, PE
Motor protection External motor protection is not required
Type of protection IP 44 (EN 60529)
Winding category Insulation category F
Temperature category TF 110 (EN 60335-2-51)
Media temperature +15 °C to +110 °C (ModulA RED)
+15 °C to +85°C (Modula BLUE)
Ambient temperature max. 40 °C
In transportation: –40 °C up to +70°C
Maximum operating The maximum operating pressure is given on the nameplate:
pressure PN 6: 6 bar
PN 10: 10 bar
PN 16: 16 bar
Noise Sound pressure level under 43 dB(A)
Leakage current The mains filter of the pump causes a leakage current
to the earth of <3.5 during operation
Power consumption
when pump switched off <3W
Performance factor cos-phi The ModulA has an integrated performance factor correction filter
(PFC). This ensures that cos-phi is always between 0.98 and 0.99
and is therefore kept very close to the ideal value 1.
EMV EN 55014-1:2006, EN 55014-2:1997, EN 61000-3-3:2008 and
(electromagnetic EN 61000-3-2:2006
compatibility)
12. Disposal
This ModulA circulation pump was developed with sustainability
in mind. This also includes waste prevention and recyclability
of materials.
This product as well as its parts must be disposed of according
to the local regulations.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Biral ModulA RED Series and is the answer not in the manual?

Biral ModulA RED Series Specifications

General IconGeneral
BrandBiral
ModelModulA RED Series
CategoryWater Pump
LanguageEnglish

Related product manuals