IXNET dialogs Operating instructions iS10 / iS20
68 38019417000 en
7
GV02
Data blocks (additional character blocks)
Non-volatile storage of 10 sets with 50 characters each possible.
GD02
Tare with value definition
CD08
Tolerance value target
CD02
Tolerance value minus
CD03
Tolerance value plus
CV06
Tolerance value group command, compare LV01 or GV01
CX01
Start tolerance control
CX02
End tolerance control
GW04
Storage number, not executable as single command
GT02
Text block (additional character), not executable as single command
7.2.1 Device functions
Device reset (reboot)
Restart the system.
Command Response
I!GX01 I!LW00|1
Zero setting of scale
Command Response
I!GX02 I!LW00|2
or
I!LV00|LW01| Error number |LW02|2|LX02
Possible errors
3002 Weighing function not executable
3030 Scale outside zero setting range