Service menu Operating instructions iS10 / iS20
92 38019417000 en
9
Key
Display presentation Process description
Third calibration point at 15 kg weighing range.
Example: 9 kg
Display of measured value for calibration point 3.
Fourth calibration point at 15 kg weighing range.
Example: 12 kg
Display of measured value for calibration point 4.
Fifth calibration point at 15 kg weighing range.
Example: 15 kg
Display of measured value for calibration point 5.
Sixth calibration point at 15 kg weighing range.
Example: 15 kg
Display of measured value for calibration point 6.
Seventh calibration point at 15 kg weighing range.
Example: 15 kg
Display of measured value for calibration point 7.
After acknowledgment of calibration point 7 the device restarts. The scale calibration is
completed.
This is how you change the suggested load ranges: Select position with and ,
change digit with and .
You can end the calibration after at least 2 calibration points with
.