109
Parameter index
Code Page Name Unit Possible value / Function Factory setting
User
setting
tdC1
65
Automatic DC injection time s 0.1 to 30 0.5 s
tFO
83
Modbus format -
8o1
8E1
8n1
8n2
8o1
8E1
8n1
8n2
8E1
tFr 55
Maximum frequency Hz 10 to 400
60 or 72 Hz
(to bFr)
tHd 38
Drive thermal state - - - - -
tHr 38
Motor thermal state % - - - -
tHt
80
Motor protection type -
ACL
FCL
Self-ventilated
Moto-ventilated
ACL
tLS
72
75
Low speed operating time s 0.1 to 999.9 -nO
tOL 52
Application Overload time delay s 0 to 100 -5 s
ttd 53
Motor thermal state threshold
% of
tHr
0 to 118 100%
ttO
83
Modbus time out - 0.1 to 30 -
10
tUn 58
Auto-tuning -
nO
YES
dOnE
No
Yes
Done
nO
UFr 56
IR compensation (law U/F) % 25 to 200 - 100%
ULn 38
Main voltage V - - - -
ULt 53
Application underload time delay s 0 to 100 -5 s
UnS 55
Rated motor voltage V 100 to 480 - 230 V
UPP
73
Wake-up threshold % 0 to 100 -0
USb
81
Undervoltage fault management -
O
1
Detected fault +
R1 open
Detected fault +
R1 closed
0
UCAL
40
Drive voltage rating - - -
--