EasyManua.ls Logo

BLEMO ER12 - Page 41

BLEMO ER12
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
42
Monitoring mode MOn
Code Name/Description Adjustment range Factory setting
MAI-
Maintenance menu (continued)
dP2
Last detected fault 2
-
This parameter describes the 2nd detected fault.
EP2
State of drive at detected fault 2
-
This parameter describes the state at the moment of the 2nd detected fault. See EP1.
dP3
Last detected fault 3
-
This parameter describes the 3rd detected fault.
EP3
State of drive at detected fault 3
-
This parameter describes the state at the moment of the 3rd detected fault. See EP1
dP4
Last detected fault 4
-
This parameter describes the 4th detected fault.
EP4
State of drive at detected fault 4
-
This parameter describes the state at the moment of the 4th detected fault. See EP1
COd
HMI Password
2 to 9999 OFF
OFF
On
Possible state value:
Code disabled
Code activated
Range 2 to 9999
If you have lost your code, please contact BLEMO.
This parameter is used to restrict access to the drive.
To lock the drive, go to the HMI Password COd parameter, enter a code within the above range.
Once activated, the code state changes to On:
The protection enables only access to rEF(see page 36
) and MOn (see page 37) modes, except when
using Software. Return to factory settings or access to FULL section are disabled,
Download configuration to Software is possible,
Upload configuration to Software is disabled.
To unlock the drive, go to the COd parameter, enter the valid code, then press ENT.
Code protection removal is then possible and carried out by entering OFF using the jog dial, then press
ENT.