General 1.5 Brief operating instructions
Page 10 BOGE Operating instructions trinity
Messages
If !!!*** xx ***!!! appears on the display
(xx = blinking number), this is an error message according to the following
table:
By pressing the ENTER key when the specific message is displayed, the
message is acknowledged and the previous display reappears – presupposed
the reason responsible for the message has been eliminated.
Parameterization codes
Num-
ber
Meaning Remedy Others
16 Pressure transmitter is defective Replace pressure transmitter
25 Balance storage Repeat software loading Replace control
32 Pressure transmitter line break Correctly connect pressure trans-
mitter (+24 V to 1)
Replace pressure transmitter or its plug
Parameter type Code Remark Page
Pressure target values 360 Highest + lowest switching point 6
Number of compressors + Interval
time
832 Set interval time to 0 h = timer operation 7
Switching times 798 All priority sequences can be set, 000 = general output lock return:
Hold arrow key and then press the ENTER key at the same time
7
Timer 010 Day: 1 = Monday, 7 = Sunday 8