12 / 32 Operating instructions Typ 2200
Betriebsanleitung Typ 2200
3.3.2 Text display in "Operation" mode
When flushing has been triggered, the following messages appear in the first line
(depending on the source):
When flushing has been triggered, the following messages may in the second
line (depending on the source):
NOTE
3S indicates that the remaining flushing/after-blowing time is 3 seconds.
If the C key is pressed, the following message appears on the display screen:
The number of flushing cycles is saved and backed up in the event of a mains
failure.
forced fl. 00:01 Remaining time till forced flushing is triggered 00 h
01 min
C - F - Q Reference to keys
Mains flushing When flushing is triggered by "Power supply on"
Manual flushing When flushing is triggered by the F key
forced flushing When flushing is triggered by time-controlled
backflushing
DP flushing When flushing is triggered by backflushing filter
differential pressure
Flush. time 3S Remaining flushing time
After bl. t. 3S Remaining after-blowing time
No.of flushes
xxxxxx cycles Number of flushing cycles