EasyManua.ls Logo

Bollfilter 2200 - P7 Cartridge Alarm Delay Time; P8 DP Alarm (Flushing Frequency Monitoring); P9 Motor Fault

Bollfilter 2200
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16 / 32 Operating instructions Typ 2200
Betriebsanleitung Typ 2200
3.5.8 P7 Cartridge alarm delay time
NOTE
This parameter is only visible with filter type P0 = 4, 5, 8, 9, 14, 15.
3.5.9 P8 DP alarm (flushing frequency monitoring)
NOTE
This parameter is only visible with filter type P0 = 3, 5, 7, 9, 11, 13, 15, 17.
3.5.10 P9 Motor fault
NOTE
This parameter is only visible with filter type P0 = 0, 6, 7, 8, 9, 12, 13, 14, 15.
Adjustable in steps of 10 seconds Range 10 - 600 s
Factory setting Initial value 30 s
Text display, line 1 P7 Cartridge al.
Text display, line 2 XXX seconds
Setting Off / On
Factory setting Initial setting "On"
Text display, line 1 P8 DP alarm
Text display, line 2 Off
or
Text display, line 2 On
Adjustable in steps of 0.01 A Range 0.10 to 0.99 A
Factory setting Initial value 0.4 A
Text display, line 1 P9 Motor fault
Text display, line 2 0000 mA

Table of Contents