14 / 32 Operating instructions Typ 2200
Betriebsanleitung Typ 2200
3.5 List and description of parameters
3.5.1 P0 Filter type
3.5.2 P1 Multiple flushing
NOTE
This parameter is only visible with filter type P0 = 6, 7, 8, 9, 10, 11, 12, 13, 14, 15.
3.5.3 P2 Time-controlled backflushing
3.5.4 P3 Time-controlled backflushing
Adjustable in steps of one Range 0 - 17
Factory setting Initial value 0
Text display, line 1 P0 filter type
Text display, line 2 6.18/6.19/6.44
Adjustable in steps of one Range 1 - 99 x
Factory setting Initial value 1
Text display, line 1 P1 multiple fl.
Text display, line 2 XXX chambers
Adjustable in steps of one hour Range 0 - 59 h
Factory setting Initial setting 2 h
Text display, line 1 P2 forced flush.
Text display, line 2 XXX hours
Adjustable in steps of one minute Range 0 - 59 min
Factory setting Initial value 0 min
Text display, line 1 P3 forced flush.
Text display, line 2 XXX minutes