6.9.4 Changing the oil in the exciter housing
Perform this maintenance work at the latest after 500
operating hours
NOTICE!
Components may get damaged!
Use only oil of the permitted specifica-
tion
Ä
Chapter 6.3 ‘Table of fuels and lubricants’
on page 53.
Protective equipment:
n
Working clothes
n
Protective gloves
Park the machine on level ground.
Park the machine in secured condition.
Clean the area around oil breather filter (1) and filling/drain
plug (2).
Tilt the machine slightly towards the oil drain side and sup-
port it safely.
Unscrew the bleeding screw.
WARNING!
Danger of burning on hot components!
Wear your personal protective outfit (protec-
tive gloves, protective clothing).
Unscrew the filling/drain plug and catch any oil running out.
Tilt the machine to the opposite side and secure it properly.
Fill in new oil.
Fig. 70
Fig. 71
Maintenance – Annual maintenance
BPR 50/55 D / BPR 60/65 D
73