Page 22 3BE390761NM – 12/11
BONNET GRANDE CUISINE
Registered Office:
Rue des Frères Lumière - Z.I Mitry Compans
F-77292 MITRY MORY Cedex
7.2 CHANGEOVER FROM ONE GAS TO ANOTHER:
According the country of installation and the category of the appliance (indicated on the firm plate), the
adaptation from one gas to another may require 2 operations:
Change of nozzles (burners) (See 7.4)
Assembling (or deassembling) of pressure switch (See 7.4)
PROCEDURE:
On the firm plate, check:
- The category (ies) of the equipment.
- The gas and pressure for which it is adjusted.
In the following chart, select:
- The country concerned.
- The gas and the category of the appliance (see above).
- The gas and the pressure for which the appliance is going to be adjusted.
- Note and carry out the required operations.
- Replace the adjustment plate (code: 308 875), and mark the new gas used.
Category and GAS OF ORIGIN
G20 20 G30 / G31 28-30/37/50
G25 / G25 20 / 25 G30 / G31 50
I
G20 20 G30 / G31 28-30/37
I
G20 / G25 20 / 25 G30 / G31
CI
* The category change is only to be carried out under the responsibility of the Company T.G.C.P. or our local agent.