ACS 553, ACS 563 Service Manual
1 689 975 295 2021-04-13Robert Bosch GmbH
17
Introduction

Vacuum pump oil must be changed with

or more often as necessary.
1. Call up the Main Menu.
2. Select  icon.
3. Select  icon.
4. Select  from the
Maintenance Menu or when prompted.
The display shows how long the vacuum
pump has operated since the last oil change.
REMAINING OIL LIFE XXX:XX (hhh:mm)
CHANGE OIL NOW?
5. Select  icon to change vacuum pump oil.
6. If the the machine displays:
WARMING OIL FOR DRAIN
allow the vacuum pump to run for two
minutes to warm up the oil.
7. If the oil is already warm, the display shows:
DRAIN USED OIL FROM PUMP AND REPLACE
WITH 250 ML OF NEW OIL REMOVE CAP TO
SPEED DRAINING OF OIL
 
there is no pressure in the machine. Then
carefully remove the cover. See Figure 1-6.
9. Remove the oil drain fitting cap (3) and
drain the oil into a suitable container for
disposal. Reinstall the oil drain cap (3) and
close tightly.
10. Slowly add vacuum pump oil to the pump

the center of the sight glass (1)
.
11. 
tightly.
12. Select  icon to continue.
13. The display show a message that indicate
to the user to check that the oil level is at
the center of the sight glass pump.
In case it is necessary to add more oil,

14. Select  icon to return to the Maintenance
Menu.


      
    
    
.
Review the laws and regulations in
your jurisdiction to determine correct disposal
procedures for pump oil. It is the responsibility
of the user to determine if a material is a
hazardous waste at the time of disposal.
The user must ensure compliance with all
applicable laws and regulations.