ACS 553, ACS 563 Service Manual
1 689 975 295 2021-04-13 Robert Bosch GmbH

Electrical

The sensors and transducers provide the
input and feedback data needed to control the
operation of unit.
Sensors include:
 the sensor is
integrated in the fan (disabled on R134a).
  weighs the refrigerant
in the ISV as a baseline for determining
the amount of refrigerant withdrawn from

refrigerant added to the system, and how
much refrigerant is available in the ISV for
use.
  supplies the
temperature of the refrigerant stored in

density.
 : identifies
R1234yf refrigerant and tests refrigerant

Transducers include:
  measures the

system.
  measures
the pressure in the oil separator to ensure
proper oil separation from the refrigerant.
 The tank pressure is read by low-side
pressure transducer.

To access the operational capability of the

computer (or network), or to update the
software as required occasionally to keep the
unit current. See “Firmware update” in the
Setup Menu section.
Refer to Figure 3-4 (Sheets 1 through 4), for a
graphical representation of the interconnection
of the electrical components.