ACS 553, ACS 563 Service Manual
1 689 975 295 2021-04-13Robert Bosch GmbH
31
Diagnostics and Testing

All units include load cell scale: ISV Load Cell.
ISV Load Cell Calibration
1. Remove the internal storage vessel (ISV)
from the scale.
2. After selecting Calibrate Load Cell from
the Service Menu by pressing  icon, the
following displays:
3. Select  icon to enter the ISV load cell
calibration.
4. Select  icon to begin the calibration.
5. Use the calibration weight as displayed for

displayed on the screen.) Select  icon to
save the displayed weight value.
 DO NOT DISTURB unit during weight
calibration.
After 5 seconds:
6. Place a 10 kg (editable) weight on the scale
and enter the weight using the keypad.
 icon to save the
entered weight value.
7. 󰀨
slope will be calculated. If either calculation
󰀨
be displayed.
󰀨
Slope Failure:
The operator is given the opportunity to retry the
