ACS 553, ACS 563 Service Manual
1 689 975 295 2021-04-13 Robert Bosch GmbH
Introduction
in Setting menu) appearing in the header on
each printout:
1. Call up the Main Menu.
2. Select icon.
3. Select icon.
4. Select in the Settings
5.
multi-tap interface on the numeric keypad:
icon acts as a backspace
key.
or arrow moves the cursor to the
right or to the left.
(0) key also acts as a spacebar.
and arrows navigate between
the rows.
6. Select icon to save the changes and
return to the Settings Menu.
7. Select
Settings Menu.
To install a new paper roll in the printer:
1. Remove the cover on the printer by pulling
out on the tab (2) as shown in Figure 1-7.
2. Remove the paper core.
3. Install the new roll of paper with the end of
the paper at the top of the roll.
4. Assemble the cover onto the printer with the
leading edge of the paper over the roller (1).
1
2
This function is used to ensure the machine’s
internal scale is always calibrated. To perform
this check make use of Bosch calibration kit
(optional) including sample weight and magnet.
First time magnet must be installed.
1. Verify the magnet on the bottom of the
2. Call up the Main Menu.
3. Select icon.
4. Select icon.
5. Select from the Mainte-
nance Menu. The machine displays:
PLACE CALIBRATION WEIGHT ON MAGNET
LOCATED ON THE BOTTOM OF MACHINE
6. Attach the calibration weight to the magnet
(1) on the bottom of the machine.
7. Select icon to continue.
.
The machine displays:
REMOVE CALIBRATION WEIGHT
FROM MAGNET LOCATED
ON THE BOTTOM OF MACHINE
Remove calibration weight from magnet
located on the bottom of machine.
9. Select icon to continue.
• If the display shows
the scale is calibration. Select icon to
return to the Maintenance Menu.
• If the display shows the
scale is out of calibration. Select
icon to retry. If calibration continues to fail,
contact an authorized service center for
assistance.
1