Technical Data
Four Wiegand interfaces for up to four card readers
(Output rating: 280 mA)
Eight relay outputs
maximum ratings (wet and dry):
switching voltage: 30 Vdc
switching current: 1,25 A
operating ratings (wet and dry):
1,25 A @ 30 Vdc
2 A @ 12 Vdc
1,5 A @ 24 Vdc
Eight analog inputs with tamper detection; only connect dry
contacts
RS-485 extension interface:
Transfer rate: 9,6 kBit/s,
no parity, 8 bit, 2 stop bit
Tamper contact for external enclosures
Power supply
10 to 30 Vdc
or via the AMC2-4W
Power consumption
AMC: 5 VA
Peripheral devices: using the PSU-60
up to 55 VA
constant load: 25 VA
Connectors
Pluggable screw connectors
Protection class
IP30