Loading...
Refer to Connecting Diagrams, page 48 for a complete wiring
diagram of the Wiegand reader interface .
Connecting Relay Outputs
To operate locks or alarm systems, the AMC2-4WE has eight
form C relay outputs. The outputs will be connected to the 3-pin
pluggable screw connectors S5, S6, S10, S11, S17, S18, S22,
and S23 - refer to Connecting Diagrams, page 48.
Figure 4.12: Location of the relay output connectors
Each relay output can operate in ‘wet’ mode, using the
AMC2-4WE's internal 12/24 Vdc power supply for external
devices or ‘dry’ mode with potential free contacts for externally
powered systems.
4.10
34 en | Installing
AMC2 Wiegand
Extension
2016-11 | AMC2-4WE | Bosch Sicherheitssysteme GmbH