2. Go to [1] Program > [1] Reporting > [4] Personal Note. The keypad shows the phone
number or email address of the selected destination.
3. Use /[PREV] or /[NEXT] to scroll though the list of destinations and go to the
destination you want to program.
4. Press [Edit] to edit the phone number or email address.
5. Delete existing characters, if necessary, and then enter the new characters.
6. Press [Save] to save the phone number or email address.
7. When the keypad shows Parameter Saved, escape from the menu.
[2] Network > [1] Ethernet > (choose the bus module or on-board) > [1]
Module Parameters menu
You can use DCHP/AutoIP or UPnP for Ethernet communication with the on-board Ethernet or
a B426. In this menu, you can enable and disable these protocols.
Default Module settings
DHCP/AutoIP Enable Yes Yes/No
UPnP Enable Yes Yes/No
IPv4 Address 0.0.0.0 _______________________________
IPv4 Subnet Mask 255.255.255.255 _______________________________
Default Gateway 0.0.0.0 _______________________________
HTTP Port Number 80 _______________________________
IPv4 Server Address 0.0.0.0 _______________________________
IPv6 Server Address 0.0.0.0 _______________________________
Module Hostname Blank _______________________________
DHCP/AutoIP Enable
B91x/B92x keypads configuration of DHCP/AutoIP Enable
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[1] Module Parameters > [1] DHCP. The keypad shows the DHCP/AutoIP current
configuration.
3. Press [ENTER] to edit the DHCP/AutoIP Enable configuration for the module.
4. Use [PREV] or [NEXT] to toggle between Yes and No.
5. Press [ENTER] while viewing the desired option to save the programming.
6. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads configuration of DHCP/AutoIP Enable
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[1] Module Parameters > [1] DHCP. The keypad shows the DHCP/AutoIP current
configuration.
3. Press [Yes] or [No] – whichever is available – to change the programming.
4. Press [Save] to save the programming.
5. When the keypad shows Parameter Saved, escape from the menu.
UPnP Enable
19.1.5
Control Panel Keypad Installer menu | en 113
Bosch Security Systems, Inc. Installation and System Reference Guide 2015.07 | 12 | F.01U.287.180