Symbol tables (PlC 200 • PG4)
Address
Symbol Comment
E 0.0 CCRESETO
Control
Reset
output
E 0.1
CCIPOSAL
Axis INPOS
E
0.2 CCSPIPOS Spindle
INl'OS
E
0.3 CCELAUFT E
axis
running
E 0.4
CCPROGAK
Programing
running
E
0.5
CCDRYRUN Test
without
movement
(dry
run)
E
O.S
CCOPCEIN
Online PlC/PC
E
0.7
CCDNCAKT
ONC_Mode
E
1.0
CCSTARTO
Start key (NO contact)
E
1.1
CCSTOPOO Stop key (NC contact)
E 1.2 CCBCDOIT BCD_Acknowledgment
E 1.3
CCPROMEM
Program
stored
E
1.4 CCEINAKT
Re-entry
cycle
active
E
1.5
CCDNCSTR
ONC
start
E
I.S
CCDNCRST
ONC
RESET
E 1.7
CCDNCSTP
ONC
STOP transverse
E
2.0 CCWMHTSl
MTB_key 1
E
2.1
CCWMHTS2 MTB_key 2
E 2.2
CCWMHTS3
MTB_key3
E
2.3 CCWMHTS4 MTB_key4
E 2.4
CCWMHTS5
MTB_key5
E 2.5
CCWMHTSG
MTB_keyS
E
2.S
CCWMHTS7
MTB_key 7
E
2.7
CCWMHTSS MTB_key8
E 3.0
CCBCAAOl
BCD-output bus address 1
E
3.1
CCBCAA02 BCD-output bus address 2
E
3.2 CCBCAA04 BCD-output bus address 4
E
3.3
CCBCAAOS
BCD-output
bus
address 8
E 3.4
CCBCAA10 BCD-output bus address 10
E
3.5
CCBCAA20 BCD-output bus address
20
E
3.S
CCBCAA40
BCD-output bus address 40
E
3.7
CCBCASTB Data valid (Strobe)
E 4.0
CCBCADOl BCD-output
bus data 1
E
4.1
CCBCAD02 BCD-output bus data 2
E
4.2 CCBCAD04 BCD-output bus data 4
E 4.3
CCBCADOS
BCD-output bus data 8
E
4.4 CCBCAD10 BCD-output bus data
10
E
4.5 CCBCAD20 BCD-output bus data
20
E
4.S
CCBCAD40 BCD-output bus data 40
E
4.7
CCBCADSO
BCD-output bus data
SO
E
5.0 CCEILJOG
GO
or
jog
in
rapid
traverse
E
5.1
CCINPOSX
X
axis
in
pas
E
5.2
CCINPOSY Y
axis
in
pes
E 5.3
CCINPOSZ
Z
axis
in
pas
E
5.4 CCINPOSE E
axis
in
pas
Address Symbol
Comment
A
0.0 CCENDSOP
Limit
switch
+
transverse
A
0.1
CCENDSON
Umit
switch
-
transverse
A
0.2 CCREFPXO
Reference
point
X
transverse
A 0.3
CCREFPYO
Reference
point
Y
transverse
A 0.4
CCREFPZO
Referee
point
Z
transverse
1
-37
CC
lOOM
User Manual
Type