Maintenance
31
Climate 2000 – 6721852026 (2024/05)
5 Maintenance
CAUTION
Danger due to electric shock or moving parts
Disconnect the power supply before carrying out any maintenance
work.
Have any maintenance steps that are not listed here carried out by an
approved installer.
5.1 Replacing the batteries
You require 2 size AAA batteries. Using rechargeable batteries is not
recommended.
Remove the battery cover ( Fig. 3).
Insert new batteries, ensuring correct polarity.
Reinstall the cover.
5.2 Cleaning the unit and the remote control
NOTICE
Damage to unit due to incorrect cleaning!
Do not directly splash or pour water onto them.
Do not use hot water, thinner, abrasive powders or strong solvents.
Clean indoor unit and remote control by wiping them with a soft
cloth.
Only have the outdoor unit cleaned by an approved contractor.
5.3 Cleaning the air filter
NOTICE
The air filter may deform in direct sunlight.
Do not expose the air filter to direct sunlight.
Clean the air filter every 2 weeks, and also before and after
decommissioning for longer periods.
Switch off the indoor unit.
Fold the top cover of the indoor unit up.
Push the air filter up and pull it out ( Fig. 4).
Take out the small air filters, if installed ( Fig. 1, [2]).
Clean the small air filters with a handheld vacuum cleaner.
Wash the large air filter with warm water and a mild cleaning agent
and dry in the shade.
Reattach the small air filter and the large air filter.
5.4 Decommissioning for longer periods
Before decommissioning for longer periods:
Clean the air filter.
Activate the self-cleaning of the indoor unit using the Clean button.
After self-cleaning, switch on the fan mode until the indoor unit is dry.
Turn off indoor unit and disconnect power supply.
Take batteries out of the remote control.
Protect the devices from dust.
5.5 Manual operation
NOTICE
Damage to units due to incorrect operation
Use of manual operation on a continuous basis is not envisaged.
This must only be used for testing purposes or in emergencies.
Only use for a short time.
Switch off the indoor unit.
Fold the top cover of the indoor unit up.
Press the key for the manual cooling mode by inserting a thin object:
Press once: unit is forced into automatic mode.
Press twice: unit is forced into cooling mode.
Press three times: indoor unit is switched off.
Use remote control to restore normal mode.