Technical information
Compress 7400i AW – 6721833372 (2021/09)
20
Table 11 Detailed sound pressure level, heat pump (alternating current)
9.2 Operating range of heat pump without auxiliary
heater
The heat pump switches off at approx. 20 °C or +35 °C. The indoor
unit or an external heat source then take over the heating and DHW
heating. The heat pump restarts if the outdoor temperature exceeds
roughly – 17 °C or falls below +32 °C. In cooling mode the heat pump
switches off at roughly +45 °C and restarts at roughly +42 °C.
Fig. 20 Heat pump without auxiliary heater
[1] Maximum flow temperature (T0)
[2] Outdoor temperature (T1)
Detailed sound pressure level (max.) 5 OR
Spacem123456810121416
Day Q=2
1)
1) No wall within a distance of 3m
dB (A) 48 42 38 36 34 32 30 28 26 25 24
Q=4
2)
2) Heat pump near the wall
dB (A)5145413937353331292827
Night Q=2
1)
dB (A) 41 35 31 29 27 25 23 21 19 18 17
Q=4
2)
dB (A)4438343230282624222120
Detailed sound pressure level (max.) 7 OR
Space m 1 2 3 4 5 6 8 10 12 14 16
Day Q=2
1)
dB (A)5044403836343230282726
Q=4
2)
dB (A) 53 47 43 41 39 37 35 33 31 30 29
Night Q=2
1)
dB (A)4337333129272523212019
Q=4
2)
dB (A) 46 40 36 34 32 30 28 26 24 23 22
<3m
>3m
35
45
50
55
60
-30
T1[°C]
T0[°C]
30
25
20
15
10
-20
0-10 10
20 30 40
1
2