Operation
25
Condens 7000 WP – 6721842519 (2022/03)
The burner was not in use for at least 28 days.
After conversion from summer to winter mode.
The next time there is a heat demand for heating, the device is held at low
thermal output for 15 minutes. The siphon filling program remains active
until the device has completed 15 minutes of operation with increased
min. capacity.
During the siphon filling program, Siphon fill. prog. appears on the
display.
The siphon filling program is interrupted when the chimney sweep mode
is called up.
9.4 Settings in the service menu
Many device functions can be set and checked in the service menu. It
includes:
Info: viewing information
Settings: general and device-specific settings
Function check: settings for function checks and start of function
checks
Reset: restoring the factory settings, resetting the maintenance
intervals
9.4.1 Operating the service menu
Opening the service menu
Press the DHW key and the Heating key simultaneously until the
service menu appears.
Closing the service menu
Press the DHW key or the Heating key.
-or-
Press the d key.
Navigating through the menu
To highlight a menu or a menu item, press the key or the key.
Press the OK key.
The menu or the menu item is displayed.
To return to the next higher menu level, press the d key.
Changing the setting values
Select the menu item with the OK key.
To select the desired value, press the or the key.
Press the OK key.
The new value is saved.
Exiting the menu item without saving values
Press the d key.
The value is not saved.
Overview of the service menu
Info
Current status
–Current fault
Fault history
–Boiler
Max. heat output
–Flow temp.
Set flow temp.
Low-loss hdr.tmp
–Act. burner mod.
Burner output
Ionisation current
Pump mod.
–Outside temp.
–Burner starts
Hours run
–System pressure
–Hot water
–Max. output
–DHW flow rate
DHW act. temp.
Hot water temp.
–Inlet temp.
–DHW set temp.
Autom. filling
–System pressure
No. of refills
Last refill dur.
Refilling active
–System
–Contr.device ver.
–Progr. unit ver.
–Code plug no.
–Code plug ver.
–Solar
Collector temp.
Cyl.temp.bottom
Collector pump
–Solar fault
Settings
Hydraulics
–Low-loss header
DHW configuration
HC1 configuration
Pump config.
Heating
–Max. heat output
Standby time
Anticyc. temp. off
Anticycle temp. on
–Hot water
Max. DHW output
–DHW circ. pump
–Cycle circ. pump
–TD-Temperature
–Start TD
–Stop TD
–Pump
Pump ctr. mode
–Min. output
–Pump overrun
Min. Sys. Pres.
Target Sys. Pres.
Special function
Ventilation func.
Siphon fill. prog.
3-WV mid. pos.
Autom. filling
–System Fill
Min. Sys. Pres.

Table of Contents

Other manuals for Bosch Condens 7000 WP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Condens 7000 WP and is the answer not in the manual?

Bosch Condens 7000 WP Specifications

General IconGeneral
BrandBosch
ModelCondens 7000 WP
CategoryBoiler
LanguageEnglish

Related product manuals