Product Information
5
Condens 7000 WP – 6721842519 (2022/03)
2Product Information
2.1 Product data for energy consumption
The product data on energy consumption can be found in the operating
instructions for the user.
2.2 About these instructions
Figures used
The figures in these instructions serve to provide general notices
regarding correct operation. These figures may slightly deviate from the
actual situation.
Product types mentioned
These instructions describe all product types of the GC7000WP.
Availability may vary depending on the country.
2.3 Type Plate
The data plate contains information on the appliance output, registration
data and serial number of the product. The data plate is on the underside
of the wall mounted boiler on the right next to the gas connection ( Fig.
1, p. 6).
2.4 Conversion of gas type
This boiler is suitable for the gas categories specified on the data plate.
If conversion of the boiler to a different gas category is allowed, this is
specified in the gas data ( § 16.2, p. 48).
2.5 Accessories
A wide range of accessories is available for this appliance.
Contact the manufacturer for more information. You will find the relevant
addresses on the back of this document.
2.6 Scope of delivery
A range of accessories is supplied with the GC7000WP.
▶ Check the heating system is intact on delivery.
▶ Check that all package contents are present.
Table 1 Scope of delivery
2.7 Pump test.
The pump starts automatically for 10 seconds every 24 hours if it is not
in use for a longer period. This procedure prevents the pump from
seizing.
2.8 Frost protection
NOTICE
Installation damage due to the effects of frost.
The heating system could freeze during a hard frost due to: mains voltage
failure, insufficient gas supply or appliance fault.
▶ Install the boiler in a frost-proof room.
▶ Drain the entire heating system if it is to be shut down for a longer
period.
The boiler is equipped with integral frost protection. This means that an
external frost protection safeguard for the boiler does not have to be
installed. The frost protection switches the boiler on at a boiler
temperature of 7 °C and switches it off at a boiler temperature of 15 °C.
This frost protection does not protect the heating system against frost.
Packaging unit Component Packaging
1 (boiler) • Wall-mounted boiler Cardboard
box
2 (accessories) • Mounting rail
• Fixing materials
•Siphon
• Condensate drain hose
• Plug (if not pre-
assembled)
• Rotary joint + gasket (2x)
• Documentation
Cardboard
box