Operation
Condens 7000 WP – 6721842519 (2022/03)
28
Settings menu
The factory settings are highlighted in the following table.
Meu item Settings/adjustment range Remark/restriction
Hydraulics
Low-loss header Connection of temperature sensor on the low loss header
• Off • Low loss header not installed in the system
• NTC on device • Low loss header installed, temperature sensor
connected to wall mounted boiler
• NTC on module • Low loss header installed, temperature sensor
connected to heating circuit module
• NTC off • Low loss header installed, but no temperature sensor
connected
DHW configuration • Not installed
• 3-way valve installed
• Cyl. prim. pump inst. after low loss hdr.
• Cyl. primary pump installed
HC1 configuration • Not installed
• Dedicated pump inst. after low loss hdr.
Pump config. • Heating pump
Heating
Max. heat output • 50 100% Maximum released heat output [%].
On natural gas devices:
▶ Measure the gas rate.
▶ Compare the measurement obtained with the setting
tables ( Chapter 16.5, page 49).
▶ Correct deviations.
Standby time • 5 … 10 … 60 min The time interval specifies the minimum waiting time
between switching on the burner and switching it on
again.
Anticyc. temp. off • 2 … 6 … 15 K The difference between the current flow temperature and
the set flow temperature until the burner is switched off.
Anticycle temp. on • -15 -6 ... 2 K The difference between the current flow temperature and
the set flow temperature until the burner is switched on.
Hot water
Max. DHW output • 50 100% Maximum approved DHW output [%].
DHW circ. pump • Off
•On
Cycle circ. pump • 1 x 3 minutes/h
• 2 x 3 minutes/h
• 3 x 3 minutes/h
• 4 x 3 minutes/h
• 5 x 3 minutes/h
• 6 x 3 minutes/h
• Permanent
The DHW circulation pump goes into operation 1 ... 6
times per hour for 3 minutes, or into continuous
operation.
TD-Temperature • 60 70 … 80 °C DHW temperature during thermal disinfection.
Start TD • Start now? Start thermal disinfection.
Stop TD • Cancel now? Cancel thermal disinfection.
Pump
Pump ctr. mode • Energy saving
• Heat demand
• Save energy: intelligent shutdown of heat pump for
heating systems with weather-compensated
controller. The heating pump is only switched on if
required.
• With heat demand: the flow temperature controller
switches the heating pump. If there is heat energy
demand, the heating pump starts up with the burner.
Min. output • 10 ... 100 % Pump output at minimum heat output. Only available if
Pump range map is set to 0.