DSA E-Series (E2700) Turning on the power and checking for problems in an E2700 controller-drive tray configuration | en 73
Bosch Sicherheitssysteme GmbH Installation manual 2015.10 | V2 | DOC
– A component that is not a field replaceable unit
failure has been detected.
SE+ dF+ blank-
– A processor DIMM failure has been detected. SE+ dF+ "--"+ CF+ Px + blank-
– A cache memory DIMM failure has been detected. SE+ dF+ "--"+ CF+ Cx + blank-
– A processor DIMM or a cache memory DIMM failure
has been detected.
SE+ dF+ "--"+ CF+ dx + blank-
– A host interface card failure has been detected. SE+ dF+ "--"+ CF+ Hx + blank-
– An incorrect number of cache backup devices have
been detected.
SE+ LC+ "--"+ CF+ Fx + blank-
Use cases Repeating sequence
Use case: Controller is suspended and there are no other
errors to report.
– All lockdown conditions OH+ Lx+ blank-
Use cases Repeating sequence
Use case: The controller is suspended because of
component errors.
– Persistent processor DIMM error correcting code
(ECC) errors have been detected.
OE+ L2+ "--"+ CF+ CX+ blank-
– Persistent cache DIMM ECC errors have been
detected.
OE+ L2+ "--"+ CF+ CX+ blank-
– Persistent processor or cache DIMM ECC errors
have been detected.
OE+ L2+ "--"+ CF+ CX+ blank-
Use cases Repeating sequence
Use case: The controller has been suspended as a result
of persistent cache backup configuration errors.
– The write-protect switch is set during cache restore. OE+ LC+ blank-
– The memory size changed with dirty data in the flash
drives.
OE+ LC+ dd+ blank-
Use cases Repeating sequence
Use case: The controller has been suspended as a result
of diagnostic errors.
A cache memory diagnostic failure has been detected. dE+ L2+ "--"+ CF+ Cx + blank-
A base controller diagnostic failure has been detected. dE+ L3+ "--"+ CF+ b1 + blank-